Λεπτομέρειες:
|
| Επισημαίνω: | 500g Capacity Hydrogen Gas Analyzer,0.09MPa Density Index Analyzer,Portable Molten Aluminum Quality Detector |
||
|---|---|---|---|
| Name: | Aluminum Alloy Density Index Analyzer DIA White HPD With Automatic Working | Time: | Less Than 3 Minutes |
| Color: | White | Voltage: | 380V |
| Size: | Standard | Material: | Iron Steel Shell |
| Total Power | <500W |
| Power Supply | 220V AC/50Hz |
| Ultimate Vacuum | -0.099MPa (relative to 1 standard atmosphere) |
| Vacuum Degree Adjustment Range | 0-0.099MPa |
| Vacuum Degree Control Accuracy | ±1 kPa |
| Sample Making Time | <5 minutes |
| Time to Reach Ultimate Vacuum | ≤1 minute |
| Maximum Allowable Temperature | 100℃ |
| Density Index Measurement Accuracy | <0.2 |
| Density Index Repeatability | <0.2 |
| Electronic Balance Maximum Range | 500g |
| Balance Measurement Accuracy | 0.001g |
| Balance Measurement Repeatability | ±0.001g |
| Balance Measurement Response Time | ≤2 seconds |
| CQY-010 | CQY-010A | CQY-011 | CQY-011A | DIA |
Υπεύθυνος Επικοινωνίας: Hanson
Τηλ.:: +8613869124558
Φαξ: 86-531-88969137